{"id":2133,"date":"2026-04-12T09:00:00","date_gmt":"2026-04-12T09:00:00","guid":{"rendered":"https:\/\/www.tgvalve.com\/?p=2133"},"modified":"2026-04-20T09:33:38","modified_gmt":"2026-04-20T09:33:38","slug":"butterfly-valve-with-tamper-switch","status":"publish","type":"post","link":"https:\/\/www.tgvalve.com\/pt\/blog\/butterfly-valve\/butterfly-valve-with-tamper-switch\/","title":{"rendered":"Como funciona uma v\u00e1lvula borboleta com interruptor anti-viola\u00e7\u00e3o em sistemas de prote\u00e7\u00e3o contra inc\u00eandio"},"content":{"rendered":"<p class=\"wp-block-paragraph\">As v\u00e1lvulas borboleta s\u00e3o comuns em sistemas de fluxo industrial devido ao seu controle r\u00e1pido. A a\u00e7\u00e3o de um quarto de volta permite o fluxo ininterrupto de \u00e1gua em sistemas de prote\u00e7\u00e3o contra inc\u00eandio. Essa a\u00e7\u00e3o \u00e9 crucial quando todo um sistema de sprinklers precisa operar continuamente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">UM <strong>V\u00e1lvula borboleta com interruptor de viola\u00e7\u00e3o<\/strong> Combina o controle mec\u00e2nico do fluxo com a supervis\u00e3o eletr\u00f4nica cont\u00ednua para garantir a seguran\u00e7a contra inc\u00eandio.\u00a0<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este guia aborda o funcionamento do interruptor de viola\u00e7\u00e3o em v\u00e1lvulas borboleta com sistemas de preven\u00e7\u00e3o de inc\u00eandio. Tamb\u00e9m explora configura\u00e7\u00f5es de fia\u00e7\u00e3o, procedimentos de substitui\u00e7\u00e3o e requisitos de conformidade com a norma NFPA 25.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>V\u00e1lvula borboleta com interruptor antiviola\u00e7\u00e3o<\/strong> Vis\u00e3o geral<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Uma v\u00e1lvula borboleta controla o fluxo de \u00e1gua em um sistema de sprinklers ou hidrantes de inc\u00eandio usando um disco interno rotativo. Quando o disco est\u00e1 paralelo \u00e0 parede do tubo, a \u00e1gua flui livremente. Girar o disco 90 graus interrompe o fluxo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Um interruptor de viola\u00e7\u00e3o, tamb\u00e9m conhecido como interruptor supervisor, \u00e9 montado diretamente no corpo da v\u00e1lvula e monitora a posi\u00e7\u00e3o do disco. Ele envia um alerta para o painel de controle de alarme de inc\u00eandio (FACP) sempre que a v\u00e1lvula se afasta de sua posi\u00e7\u00e3o normal de abertura.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A maioria dos conjuntos inclui dois interruptores independentes. O primeiro est\u00e1 conectado ao painel de controle de alarme de inc\u00eandio (FACP). O segundo est\u00e1 conectado a um dispositivo auxiliar, como uma sirene sonora ou uma luz estrobosc\u00f3pica visual. Essa configura\u00e7\u00e3o de interruptor duplo \u00e9 exigida em muitas jurisdi\u00e7\u00f5es e est\u00e1 em conformidade com as disposi\u00e7\u00f5es do Cap\u00edtulo 21 da NFPA 72 sobre sinaliza\u00e7\u00e3o de supervis\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A v\u00e1lvula e o interruptor formam um conjunto monitorado. Este \u00e9 um requisito fundamental para o <strong>V\u00e1lvula borboleta com interruptor anti-viola\u00e7\u00e3o para prote\u00e7\u00e3o contra inc\u00eandio.<\/strong>. Instala\u00e7\u00f5es comerciais, industriais e edif\u00edcios altos devem cumprir esses requisitos de seguran\u00e7a contra inc\u00eandio.\u00a0<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Como funciona o interruptor antiviola\u00e7\u00e3o: mecanismo e fia\u00e7\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">O interruptor de viola\u00e7\u00e3o utiliza um bra\u00e7o atuador com mola que entra em contato com a haste da v\u00e1lvula ou com o indicador de posi\u00e7\u00e3o do volante. O bra\u00e7o atuador permanece em posi\u00e7\u00e3o neutra quando a v\u00e1lvula est\u00e1 totalmente aberta. Nesse estado, os contatos do interruptor permanecem em sua posi\u00e7\u00e3o normal de supervis\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se o disco da v\u00e1lvula girar mais de uma ou duas voltas a partir da posi\u00e7\u00e3o totalmente aberta, o bra\u00e7o do atuador se deflete. Essa deflex\u00e3o altera o estado do contato da chave e aciona um alarme de supervis\u00e3o no painel de controle de alarme de inc\u00eandio (FACP).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O pr\u00f3prio interruptor n\u00e3o aciona um alarme de inc\u00eandio. Em vez disso, ele envia um sinal de supervis\u00e3o distinto. Isso informa \u00e0 equipe de manuten\u00e7\u00e3o que um problema est\u00e1 ocorrendo. <a href=\"https:\/\/www.tgvalve.com\/pt\/blog\/butterfly-valve\/comparison\/butterfly-valve-throttling-vs-isolation-when-to-use-as-a-control-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">v\u00e1lvula de controle<\/a> Requer aten\u00e7\u00e3o.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Diagrama de fia\u00e7\u00e3o da v\u00e1lvula borboleta com interruptor anti-viola\u00e7\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Um diagrama de fia\u00e7\u00e3o padr\u00e3o para v\u00e1lvula borboleta com interruptor de viola\u00e7\u00e3o mostra o seguinte esquema de circuito:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Conecte o terminal 1 (C \u2013 Comum) e o terminal 2 (NC \u2013 Normalmente Fechado)<\/strong>Este interruptor est\u00e1 conectado em s\u00e9rie com a zona de entrada de supervis\u00e3o do FACP.<\/li>\n\n\n\n<li><strong>Terminal 3 do interruptor (NA \u2013 Normalmente Aberto)<\/strong>Este terminal de interruptor est\u00e1 conectado a um dispositivo auxiliar opcional (buzina, campainha ou luz indicadora).<\/li>\n\n\n\n<li><strong>Resistor de fim de linha (EOLR)<\/strong>Este componente \u00e9 instalado de acordo com as especifica\u00e7\u00f5es do fabricante do painel de controle de alarme de inc\u00eandio (FACP), normalmente com resistor de 4,7 k\u03a9 ou 10 k\u03a9, para permitir a supervis\u00e3o da fia\u00e7\u00e3o Classe B.<\/li>\n\n\n\n<li><strong>Bitola do fio:<\/strong> Os requisitos s\u00e3o de no m\u00ednimo 18 AWG, par tran\u00e7ado, conforme a Tabela 12.3.2 da NFPA 72.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Antes de efetuar a fia\u00e7\u00e3o, \u00e9 importante consultar o diagrama espec\u00edfico do fabricante da v\u00e1lvula borboleta com interruptor anti-viola\u00e7\u00e3o. As etiquetas dos terminais variam entre os conjuntos com certifica\u00e7\u00e3o UL de diferentes fabricantes.<\/p>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n  <title>Destaque do produto Hero<\/title>\n  <style>\n    .hero-card {\n      display: flex;\n      flex-wrap: wrap;\n      align-items: center;\n      background: #f7f8fa;\n      border-radius: 16px;\n      box-shadow: 0 6px 20px rgba(0, 0, 0, 0.05);\n      padding: 24px;\n      max-width: 900px;\n      margin: 40px auto;\n      font-family: 'Poppins', Arial, sans-serif;\n      text-decoration: none;\n      color: inherit;\n    }\n\n    .hero-image {\n      width: 220px;\n      height: auto;\n      border-radius: 12px;\n      object-fit: cover;\n      flex-shrink: 0;\n    }\n\n    .hero-content {\n      padding-left: 24px;\n      flex: 1;\n      min-width: 260px;\n    }\n\n    .hero-title {\n      font-size: 1.6rem;\n      font-weight: bold;\n      margin-bottom: 12px;\n      color: #222;\n    }\n\n    .hero-description {\n      font-size: 1rem;\n      color: #555;\n      margin-bottom: 18px;\n      white-space: pre-line;\n      line-height: 1.6;\n    }\n\n    .hero-description b {\n      color: #222;\n    }\n\n    .hero-link {\n      display: inline-block;\n      padding: 10px 20px;\n      background-color: #0066cc;\n      color: #fff;\n      text-decoration: none;\n      border-radius: 8px;\n      font-weight: bold;\n      transition: background 0.2s ease-in-out;\n    }\n\n    .hero-link:hover {\n      background-color: #004c99;\n    }\n\n    @media (max-width: 640px) {\n      .hero-card {\n        flex-direction: column;\n        text-align: center;\n      }\n\n      .hero-content {\n        padding-left: 0;\n        padding-top: 20px;\n      }\n\n      .hero-image {\n        width: 100%;\n        max-width: 280px;\n      }\n    }\n  <\/style>\n<\/head>\n<body>\n\n<a class=\"hero-card\" href=\"https:\/\/www.tgvalve.com\/pt\/product\/fire-safety-double-offset-butterfly-valve\/\" target=\"_blank\">\n  <img decoding=\"async\" class=\"hero-image\" src=\"https:\/\/www.tgvalve.com\/wp-content\/uploads\/2025\/06\/Double-Offset-Butterfly-Valve-%E2%80%93-1-800x800.webp\" alt=\"\">\n  <div class=\"hero-content\">\n    <div class=\"hero-title\">V\u00e1lvula borboleta de compensa\u00e7\u00e3o dupla para seguran\u00e7a contra inc\u00eandio<\/div>\n    <div class=\"hero-description\">\n<b>Di\u00e2metro nominal: <\/b> 2\u2033 a 64\u2033  \n<b>Material:  <\/b> WCB, CF8, CF3, CF8M, CF3M, 4A, 5A, 6A, Al-Bronze\n<b>Modo de condu\u00e7\u00e3o: <\/b> Engrenagem sem-fim, el\u00e9trica, pneum\u00e1tica\n    <\/div>\n    <span class=\"hero-link\">Ver produto<\/span>\n  <\/div>\n<\/a>\n\n<\/body>\n<\/html>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Guia passo a passo para substitui\u00e7\u00e3o de v\u00e1lvula borboleta com interruptor anti-viola\u00e7\u00e3o<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Quando o interruptor falhar no teste funcional, o interruptor de viola\u00e7\u00e3o da v\u00e1lvula deve ser substitu\u00eddo. Para refer\u00eancia, o procedimento abaixo se aplica a conjuntos com extremidades ranhuradas. Consulte a ficha t\u00e9cnica do produto e siga os passos espec\u00edficos para o seu modelo de v\u00e1lvula.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Consulte o diagrama para seguir o passo a passo. <a href=\"https:\/\/www.tgvalve.com\/pt\/blog\/butterfly-valve\/how-to-install-a-butterfly-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">guia de instala\u00e7\u00e3o<\/a>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"670\" src=\"https:\/\/www.tgvalve.com\/wp-content\/uploads\/2026\/04\/Butterfly-valve-with-tamper-switch-diagram-for-replacement-guide-1200x670.webp\" alt=\"\" class=\"wp-image-2135\" srcset=\"https:\/\/www.tgvalve.com\/wp-content\/uploads\/2026\/04\/Butterfly-valve-with-tamper-switch-diagram-for-replacement-guide-1200x670.webp 1200w, https:\/\/www.tgvalve.com\/wp-content\/uploads\/2026\/04\/Butterfly-valve-with-tamper-switch-diagram-for-replacement-guide-800x446.webp 800w, https:\/\/www.tgvalve.com\/wp-content\/uploads\/2026\/04\/Butterfly-valve-with-tamper-switch-diagram-for-replacement-guide-500x279.webp 500w, https:\/\/www.tgvalve.com\/wp-content\/uploads\/2026\/04\/Butterfly-valve-with-tamper-switch-diagram-for-replacement-guide-300x167.webp 300w, https:\/\/www.tgvalve.com\/wp-content\/uploads\/2026\/04\/Butterfly-valve-with-tamper-switch-diagram-for-replacement-guide-768x429.webp 768w, https:\/\/www.tgvalve.com\/wp-content\/uploads\/2026\/04\/Butterfly-valve-with-tamper-switch-diagram-for-replacement-guide-1536x857.webp 1536w, https:\/\/www.tgvalve.com\/wp-content\/uploads\/2026\/04\/Butterfly-valve-with-tamper-switch-diagram-for-replacement-guide-18x10.webp 18w, https:\/\/www.tgvalve.com\/wp-content\/uploads\/2026\/04\/Butterfly-valve-with-tamper-switch-diagram-for-replacement-guide-134x75.webp 134w, https:\/\/www.tgvalve.com\/wp-content\/uploads\/2026\/04\/Butterfly-valve-with-tamper-switch-diagram-for-replacement-guide-480x268.webp 480w, https:\/\/www.tgvalve.com\/wp-content\/uploads\/2026\/04\/Butterfly-valve-with-tamper-switch-diagram-for-replacement-guide.webp 2048w\" sizes=\"auto, (max-width:767px) 480px, (max-width:1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Conclus\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">As \u00e1reas industriais e comerciais exigem <strong>V\u00e1lvula borboleta com interruptor anti-viola\u00e7\u00e3o para prote\u00e7\u00e3o contra inc\u00eandio.<\/strong>.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A TG Valve fornece v\u00e1lvulas com certifica\u00e7\u00e3o UL e aprova\u00e7\u00e3o FM. <strong>V\u00e1lvulas borboleta com interruptor anti-viola\u00e7\u00e3o<\/strong> unidades em ranhuras, <a href=\"https:\/\/www.tgvalve.com\/pt\/blog\/butterfly-valve\/comparison\/wafer-vs-lug-butterfly-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">wafer<\/a>, e configura\u00e7\u00f5es roscadas. Os tamanhos de tubos dispon\u00edveis variam de <a href=\"https:\/\/www.tgvalve.com\/pt\/blog\/butterfly-valve\/choosing-the-right-butterfly-valve-size\/\" target=\"_blank\" rel=\"noreferrer noopener\">1 polegada a 12 polegadas<\/a> (25 mm a 300 mm).\u00a0<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Todos os conjuntos s\u00e3o enviados com chave supervisora SPDT calibrada de f\u00e1brica, acesso \u00e0 fia\u00e7\u00e3o de terminal duplo e um <strong>Diagrama da v\u00e1lvula borboleta do fabricante com interruptor de viola\u00e7\u00e3o<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Como fabricante especializada, a TG Valve mant\u00e9m uma instala\u00e7\u00e3o com <a href=\"https:\/\/www.tgvalve.com\/pt\/quality\/\" target=\"_blank\" rel=\"noreferrer noopener\">ISO 9001<\/a> A certifica\u00e7\u00e3o garante uma gest\u00e3o de qualidade rigorosa. Seus processos de produ\u00e7\u00e3o e produtos est\u00e3o em conformidade com normas internacionais, incluindo CE, API e TS.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/www.tgvalve.com\/pt\/contact\/\" style=\"background-color:#1b4ca2\" target=\"_blank\" rel=\"noreferrer noopener\">Obtenha um or\u00e7amento gratuito<\/a><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Butterfly valves are common in industrial flow systems due to their rapid control. The quarter-turn action allows fire protection systems uninterrupted water flow. This action is<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":2134,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2133","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-butterfly-valve"],"_links":{"self":[{"href":"https:\/\/www.tgvalve.com\/pt\/wp-json\/wp\/v2\/posts\/2133","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tgvalve.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tgvalve.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tgvalve.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tgvalve.com\/pt\/wp-json\/wp\/v2\/comments?post=2133"}],"version-history":[{"count":1,"href":"https:\/\/www.tgvalve.com\/pt\/wp-json\/wp\/v2\/posts\/2133\/revisions"}],"predecessor-version":[{"id":2136,"href":"https:\/\/www.tgvalve.com\/pt\/wp-json\/wp\/v2\/posts\/2133\/revisions\/2136"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tgvalve.com\/pt\/wp-json\/wp\/v2\/media\/2134"}],"wp:attachment":[{"href":"https:\/\/www.tgvalve.com\/pt\/wp-json\/wp\/v2\/media?parent=2133"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tgvalve.com\/pt\/wp-json\/wp\/v2\/categories?post=2133"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tgvalve.com\/pt\/wp-json\/wp\/v2\/tags?post=2133"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}